From the number the converter returns to degrees, volts and percent moisture. With a soil sensor calibrated on two points and an analog temperature sensor, both read with the ADS1115.

By Ada Intelisano · informaticait.it technical team

Download the PDF (A4, 4 pages) Free to print and share, without changes — CC BY-ND 4.0
In short
  • Every conversion takes two steps: from the number to volts (depends on the converter) and from volts to the quantity (depends on the sensor).
  • If the datasheet gives a formula, use it: the TMP36 gives 0.5 V at 0 °C and 10 mV per degree.
  • If there is no formula, you calibrate on two points: read the soil sensor in the air (0 %) and in water (100 %), then draw the straight line.
  • The conversion does not make the sensor more accurate: 16 bits on a ±3 °C TMP36 are still ±3 °C.

Step 1: from the number to volts

The converter returns an integer. To get volts you multiply it by the value of one step, that is the full scale divided by the number of levels:

ConverterOne step is worthVolts =
Arduino UNO, 5 V reference5 ÷ 1024 ≈ 4.9 mVreading × 5 ÷ 1024
ESP32 (Arduino)the chip works it out with its calibrationanalogReadMilliVolts(pin) ÷ 1000
ADS1115, GAIN_ONE (±4.096 V)4.096 ÷ 32768 = 0.125 mVads.computeVolts(reading)

Step 2: from volts to the quantity

TMP36: 10 mV per degree-40025501001250.00.51.01.52.0temperature (°C)output (V)0 °C → 0.5 V25 °C → 0.75 Vinformaticait.it

With the datasheet formula. The Analog Devices TMP36 gives a voltage proportional to temperature: 500 mV at 0 °C and 10 mV for every degree, so T = (V − 0.5) × 100. At 25 °C the output is 750 mV. It runs on 2.7 to 5.5 V and draws less than 50 µA.

Soil sensor: calibration line1.01.52.02.53.00255075100measured voltage (V)moisture (%)air = 0 %water = 100 %1.69 V → 67 %informaticait.it

With two-point calibration. The DFRobot SEN0193 capacitive sensor gives a voltage that drops as moisture rises, but every unit is a bit different and there is no formula. DFRobot explains how to do it: read the sensor in the air (dry soil, 0 %) and in a glass of water without going past the line (100 %). Between the two points you draw a straight line: moisture = (Vair − V) ÷ (Vair − Vwater) × 100.

Complete example with the ADS1115

Calibration: 2.54 V in the air, 1.27 V in water (these are the values from the DFRobot example, 520 and 260 on the Arduino UNO).
Channel A0 reads 13520 → 13520 × 0.125 mV = 1.690 V → moisture = (2.54 − 1.69) ÷ (2.54 − 1.27) × 100 = 67 %.
Channel A1 (TMP36) reads 5960 → 5960 × 0.125 mV = 0.745 V → T = (0.745 − 0.5) × 100 = 24.5 °C.

The capacitive soil sensor

DFRobot SEN0193A+−Capacitive Soil MoistureSensor V1.0DFRobotdo not insert past this linepart that goes into the soilA + −98 × 23 mminformaticait.it

DFRobot SEN0193: 98 × 23 mm, 3.3 to 5.5 V supply (it has its own regulator), 3-pin connector A, +, −. The components on the upper part are not waterproof: push it into the soil only up to the white line. DFRobot warns that the reading also changes with depth and with how compact the soil is: the calibration holds for the way you install it.

Wiring with the ESP32 and the ADS1115

ESP32 + ADS1115: soil sensor on A0, TMP36 on A1ESP32-WROOM-323V3GNDEN23VP22VNTX34RX352132GND3319251826527171416124GND0132D215D3D1CMDD05VCLKonADS111516-bit ADCVINGNDSCLSDAADDRALRTA+A3A2A1A0A−A+−Capacitive Soil MoistureSensor V1.0DFRobotTMP36TMP36+Vs Vout GNDA0A121223V3SEN0193informaticait.it

Everything at 3.3 V: the ADS1115, the soil sensor and the TMP36 take their power from the ESP32's 3V3. The soil sensor goes to input A0, the middle output of the TMP36 to A1. With the Arduino UNO you use 5 V and the same sketch.

The sketch

// From bits to real values with the ADS1115:
//  A0 = capacitive soil moisture sensor (DFRobot SEN0193): two-point calibration, air and water
//  A1 = TMP36 analog temperature sensor: 10 mV per degree, 500 mV at 0 degrees
// Same sketch for Arduino UNO and ESP32. Library: Adafruit ADS1X15.
#include <Adafruit_ADS1X15.h>

Adafruit_ADS1115 ads;

// Calibration: write YOUR two readings in volts here (see the guide, step 2).
// These are the values from the DFRobot example (520 and 260 on Arduino UNO, that is 2.54 V and 1.27 V):
// every sensor is a little different, so measure yours.
const float V_AIR = 2.54;     // dry sensor, in the air
const float V_WATER = 1.27;   // sensor in a glass of water, not past the line

void setup() {
  Serial.begin(115200);
  if (!ads.begin(0x48)) {
    Serial.println("ADS1115 not found");
    while (true) delay(1000);
  }
  ads.setGain(GAIN_ONE);     // +/-4.096 V full scale, 1 bit = 0.125 mV
}

void loop() {
  // 1) bits -> volts
  float vSoil = ads.computeVolts(ads.readADC_SingleEnded(0));
  float vTmp36 = ads.computeVolts(ads.readADC_SingleEnded(1));

  // 2) volts -> real value
  // moisture: straight line through the two calibration points (more water = lower voltage)
  float moisture = (V_AIR - vSoil) / (V_AIR - V_WATER) * 100.0;
  moisture = constrain(moisture, 0.0, 100.0);
  // temperature: formula from the TMP36 datasheet
  float tempC = (vTmp36 - 0.5) * 100.0;

  Serial.print("Soil: ");
  Serial.print(vSoil, 3);
  Serial.print(" V = ");
  Serial.print(moisture, 0);
  Serial.print(" %   TMP36: ");
  Serial.print(vTmp36, 3);
  Serial.print(" V = ");
  Serial.print(tempC, 1);
  Serial.println(" degrees C");
  delay(1000);
}

Calibrate first: leave the sensor in the air and note the voltage printed, then put it in a glass of water up to the line and note the second one. Write the two values in V_AIR and V_WATER and upload the sketch again.

Other sensors, other formulas

SensorFrom volts to quantityGood to know
TMP36T = (V − 0.5) × 1002.7–5.5 V; in the TO-92 package (grade G) the maximum error is ±3 °C at 25 °C
LM35T = V × 100 (0 V at 0 °C)needs at least 4 V of supply: with the ESP32 at 3.3 V it is outside its specifications
NTC 10 kΩ, B 3950resistance from the divider, then the Beta equation: 1/T = 1/T0 + ln(R/R0)/B (T in kelvin, T0 = 298.15 K)away from 25–50 °C the Beta formula drifts from the manufacturer's table (calculated on the Adafruit 4890 table: about 0.5 °C at 0 °C, over 2 °C at −40 °C); “3950” thermistors from different brands do not have the same curve
Voltage dividerVin = V × (R1 + R2) ÷ R2for voltages higher than the converter's supply, for example a battery

Common mistakes

What happensWhyFix
Moisture above 100 % or below 0 %the reading falls outside the two calibration pointsclamp the result (constrain) or calibrate again
The soil sensor fails after a few weekspushed in past the line: the electronics at the top are not waterproofrespect the line; DFRobot suggests heat-shrink tubing
Different readings when you move the sensordepth and soil compactness change the outputcalibrate the sensor in the position where it will stay
LM35 reading wrong with the ESP32powered at 3.3 V, below the 4 V minimumuse the TMP36, which works from 2.7 V
Temperature “accurate” to a hundredth but wrongthe ADC resolution is not the sensor's accuracycompare with the ±°C in the datasheet
NTC reading a few tenths too highself-heating: the divider current warms it uppower the divider only during the reading
The method works everywhere. Photoresistors, pressure sensors with a voltage output, amplified load cells: if the datasheet has a formula, use it; otherwise, two known points and a straight line. For strongly curved sensors you use more points or a lookup table.
Sources: DFRobot, wiki and schematic of the SEN0193 “Capacitive Soil Moisture Sensor” (calibration procedure and warnings) · Analog Devices, TMP35/TMP36/TMP37 datasheet (Rev. H); Texas Instruments, LM35 datasheet (SNIS159H) · Texas Instruments, ADS111x datasheet (SBAS444E); Adafruit, Adafruit_ADS1X15 library · Adafruit, “Thermistor” guide and datasheet of thermistor 4890 (resistance-temperature table) · Microchip, ATmega328P datasheet; Espressif, Arduino-ESP32 documentation (ADC)