Key features
- MEMS (micro-electromechanical system) technology: compact size, low power consumption (under 20 mA) and fast response
- Qualitative measurement of smoke concentration with analog voltage output
- Response time under 15 seconds
- Can be combined with the other sensors of the Fermion MEMS series (HCHO, CO, CH4, VOC, NH3, H2S, EtOH, smoke, odour, H2, NO2)
Technical specifications
- Gases detected: ethanol, smoke particulates
- Detection range: 10–1000 ppm (qualitative)
- Supply voltage: 3.3–5 V DC
- Operating current: < 20 mA
- Output: analog voltage (0–5 V)
- Response time: < 15 s
- Sensitivity: R0/Rs ≥ 3 at 200 ppm ethanol
- Operating temperature: -10 to +50 °C
- Operating humidity: 15–90% RH
- Lifetime: over 5 years of continuous use
- Dimensions: 13 × 13 × 2.5 mm
Typical uses
IoT smoke alarm prototypes, overheating detection on industrial equipment, kitchen and laboratory safety, smart home ventilation control.
Precautions
- Remove the protective film before use
- Avoid volatile silicone compound vapours (silicone adhesives and rubber, hair gel), high concentrations of corrosive gases (H2S, SOx, Cl2, HCl), contamination by alkalis and halogens
- Avoid water, condensation, freezing, excessive vibration, impacts and drops
- After a long period of non-use, preheat the sensor for at least 24 hours
- Qualitative measurement only: do not use in systems involving personal safety
Package contents
- 1 × Fermion MEMS smoke sensor (breakout)
- 1 × 2.54 mm pitch pin header
Nota sulle fotoLe foto sono scattate da noi o fornite dal produttore e verificate sul prodotto reale. Il prodotto ricevuto può differire nell'aspetto (colore, marcature, confezione o lotto), mantenendo funzioni e caratteristiche tecniche dichiarate dal produttore.